| Hp Technik GmbH工业泵 |  | | 德国Hp Technik GmbH工业泵A 产品系列: |  | | Series PON Technical Selection Chart: Scaled Drawings Direction of rotation I = indirect – counterclockwise D = direct – clockwise Nozzle Port R = on the right-hand side L = on the left-hand side The direction of rotation can only be changed in the factory. Therefore please assure that you state the desired direction of rotation and the direction of the nozzle port as per the size chart sheet when ordering! Standard design of the pump for two pipe installation, design for one pipe installation can be changed individually (see Operation Installation and Maintenance Instructions). All hp-oilburner pumps series PON can be equiped with electric heating, serie H3, at the factory. | | Size | Capacity l/h at n = 2800 min-1 viscosity 5 cSt. | direction of rotation | nozzle port | order number | max. allowed pump RPM(min-1 | gear rotor size Ø | initial pump breakaway touque(Nm) | net weight (kg) | | at 9 bar | at 30 bar | at 40 bar | I-L | I-R | D-L | D-R | | PON 3 | 90 | 60 | 50 | D = direct-clockwise | R | 0130601 | 0130611 | 0140601 | 0140611 | 3.600 | 25 | 1,2 | 5,0 | | PON 4 | 160 | 130 | 120 | | | 0130602 | 0130612 | 0140602 | 0140612 | 3.600 | 25 | 1,2 | 5,0 | | PON 6 | 240 | 200 | 190 | I = indiret-counterclockwise | L | 0130603 | 0130613 | 0140603 | 0140613 | 3.600 | 25 | 1,2 | 5,0 | | PON 7 | 320 | 270 | 260 | | | 0130604 | 0130614 | 0140604 | 0140614 | 3.600 | 25 | 1,2 | 5,0 | | Size | Capacity l/h at 9 bar(l/h) | connection | pressure range(bar) | RPM(min-1 | medium | accessories | | nozzle | suction side | bypass | manometer | | PON 3 | 90 | 1/4" | 1/2" | 1/2" | 1/8" | 1 = 1-4 | 1 = 1.400 | O = fuel oil EL + L | H3 - heating element PON | | PON 4 | 160 | 1/4" | 1/2" | 1/2" | 1/8" | 2 = 2-9 | | MGO/MDO | E-one pipe installation | | PON 6 | 240 | 1/4" | 1/2" | 1/2" | 1/8" | 3 = 6-25 | 2 = 2.800 | 5 = fuel oil M + S | Z - two pipe installation | | PON 7 | 320 | 1/4" | 1/2" | 1/2" | 1/8" | 4 = 14-40 | | | | | Conversation Table Suntec - hp-TECHNIK | | Suntec | | hp-TECHNIK | | Suntec | | hp-TECHNIK | | | PON 3-D | | | | PON 3-I | | E4/J4 | ==> | PON 4-D | | E4/J4 | ==> | PON 4-I | | E6/J6 | ==> | PON 6-D | | E6/J6 | ==> | PON 6-I | | E7/J7 | ==> | PON 7-D | | E7/J7 | ==> | PON 7-I | |  | hp Industrial Pump Program An internal gear rotor drives an eccentric, externally toothed gear. The rotor and the toothed wheel are sealed with a fixed crescent. Internal gear pumps have been in use for more than 40 years and are used in many areas of industry because of their favorable construction and design. | Series B  Series VB  Series VBR  Series NV  Series UHE  | | | Key for hp-Special Pumps  | A total of 5 series of hp industrial pumps and hp special pumps are available. |  Series B  |  Series VBR with Overflow  |  Series UHE with Overflow  | |  |  Series VB with Overflow Valve  |  Series NV with Overflow  | |  | Applications: | | | Oil Burning Systems As oil burner pumps, closed circular pipe and transfer pumps for all fuel oils EL, L, M, S, ES, coaltar oils, lignite tar, oils, biofuels, kerosene. | | | Machine Construction As hydraulic pumps in hydraulic control units, as lubricating pumps for lubricating oils and greases, as cooling water pumps for water-oil emulsions. | | | Mineral Oil Industry As feed pumps for oils, grease, tar and bitumen. | | | Ship Building As lubricating oil pumps and booster pumps for lubricating, diesel and heavy oils. | | | Discharge Range: 45 to 6000 l/h Operating Pressures: 0 - 40 bar Temperatures: up to 150°C Compatible with Santex TA | | In addition to the applications and pumping mediums mentioned here, hp industrial pumps are used in many other industries – pumping a wide variety of different mediums. | | Material: |  | Advantages: | Pump casings are made of hydraulic cast iron (GG 25); rotor is of CK 70; pinion is of 16 Mn Cr 5; axial face seal of cast iron/coal; up to 150°C Viton. | | Self-priming, self-lubricating, practically non-pulsating, quiet-running, practically maintenance-free, pressure proof and vacuum-tight Shaft seals. | | | |  | for determination of the order numbers: | | Series | Discharge l/h | Direction of rotation viewed from Shaft | Pressure settings bar | Speed of Rotation | Medium | Special Production, Accessories (add code letters consecutively) | 1400 min-1 0 bar | 2800 min-1 0 bar | | B | VB | VBR | NVBR | P | 45 | P | 90 | D = clockwise rotation I = counter- clockwise rotation | 0 = 0,5 - 1,5 1 = 1 - 4 2 = 2 - 9 3 = 6 - 25 4 = 15 - 40 | 9= 9800 min-1 1= 1400 min-1 2= 2800 min-1 | 0= heating oil EL + L + kerosene heating oil 5 = heating oil M + S + ES 6= coaltar oil | H1 =electric heating integrated without thermostat t max=70K. BH1 = drilling for H1 Sc = quick-closing valve | | B | VB | VBR | NVBR | M | 80 | M | 160 | | B | VB | VBR | NVBR | G | 120 | G | 240 | | B | VB | VBR | NVBR | F | 160 | F | 320 | | | | | | | | | | BG | VBG | VBGR | NVBGR | PP | 150 | PP | 300 | | BG | VBG | VBGR | NVBGR | PZ | 200 | PZ | 400 | | BG | VBG | VBGR | NVBGR | P | 300 | P | 600 | | BG | VBG | VBGR | NVBGR | MZ | | MZ | 850 | | BG | VBG | VBGR | NVBGR | M | 450 | M | 900 | | BG | VBG | VBGR | NVBGR | GZ | | GZ | 1100 | | BG | VBG | VBGR | NVBGR | G | 600 | G | – | | | | | | | – | – | | BH | VBH | VBHR | NVBHR | P | 1000 | – | – | | BH | VBH | VBHR | NVBHR | M | 1500 | – | – | | BH | VBH | VBHR | NVBHR | G | 2000 | – | – | | | | | | | | | | BHG | VBHG | VBHGR | – | P | 3000 | – | – | | BHG | VBHG | VBHGR | – | PZ | 3700 | – | – | | BHG | VBHG | VBHGR | – | M | 4500 | – | – | | BHG | VBHG | VBHGR | | G | 6000 | – | – | | | | | | | | | | UHE-A2 | | | | PZ | 200 | PZ | 400 | | UHE-A3 | – | – | – | P | 300 | P | 600 | | UHE-A4 | – | – | – | M | 450 | M | 900 | | UHE-A5 | – | – | – | GZ | 550 | GZ | 1100 | | | | Example for ordering: hp- impeller pump, Series VB, with capacity of 450 l/h at 1400 min-1, fuel oil, direction of rotation "counterclockwise," pressure settings 2 (15-40 bar). | | Series E pression: VB GM - 1 - 4 - 10 max permitted suction pressure on suction of the connection of the pump is -0,6 bar. Caution! Gas secretions arise already at -0,4 bar. | Conversion Table Suntec (TA-Series) — hp-Technik (UHE-Series) | | Suntec | | hp-Technik | | Suntec | | hp-Technik | | TA 2 A |  | UHE-A2-PZ-D | | TA 2 C |  | UHE-A2-PZ-I | | TA 3 A |  | UHE-A3-P-D | | TA 3 C |  | UHE-A3-P-I | | TA 4 A |  | UHE-A4-M-D | | TA 4 C |  | UHE-A4-M-I | | TA 5 A |  | UHE-A5-GZ-D | | TA 5 C |  | UHE-A5-GZ-I | |  Technical Selection Chart: Scaled Drawings Direction of rotation viewed from Shaft I = indirect – counterclockwise D = direct – clockwise The direction of rotation can only be changed in the factory. Therefore please assure that you state the desired direction of rotation as per the size chart/sheet when ordering! | | hp internal gear pumps up to 40 bar (Direction I = indirect - counterclockwise) | Pump Series B Size: | Viscosity: 6 mm2 sec-1 at 20° C | Gear Rotor Size Ø | Shaft Ø | Threaded Connection for (S/A) | Mano- meter Con- nection | max. allowed Pump RPM (min-1) at I/D | Net weight (kg) at I/D | n = 1400 min-1 Discharge l/h | n = 2800 min-1 Discharge l/h | | at 9 bar | at 30 bar | at 40 bar | Article No. I | at 9 bar | at 30 bar | at 40 bar | Article No. I | | BP | 45 | 30 | 20 | 011/0002 | 90 | 60 | 50 | 013/0002 | 25 | 12 | 3/8" | – | 2800 | 1,8 | | BM | 80 | 60 | 50 | 011/0003 | 160 | 130 | 120 | 013/0003 | 25 | 12 | 3/8" | – | 2800 | 1,8 | | BG | 120 | 100 | 80 | 011/0004 | 240 | 200 | 190 | 013/0004 | 25 | 12 | 3/8" | – | 2800 | 1,8 | | BF | 160 | 140 | 120 | 011/0005 | 320 | 270 | 260 | 013/0005 | 25 | 12 | 3/8" | – | 2800 | 1,8 | | | | | | | | | | | | | | | | | BG PP | 150 | 100 | 80 | 011/0052 | 300 | 240 | 210 | 013/0052 | 38 | 12 | ½" | – | 2800 | 2,6 | | BG PZ | 200 | 160 | 140 | 011/0053 | 400 | 310 | 280 | 013/0053 | 38 | 12 | ½" | – | 2800 | 2,6 | | BG P | 300 | 240 | 200 | 011/0019 | 600 | 520 | 480 | 013/0019 | 38 | 12 | ½" | – | 2800 | 2,6 | | BG MZ | – | – | – | – | 850 | 750 | 700 | 013/0068 | 38 | 12 | ½" | – | 2800 | 2,6 | | BG M | 450 | 390 | 360 | 011/0020 | 900 | 850 | 730 | 013/0020 | 38 | 12 | ½" | – | 2800 | 2,6 | | BG GZ | – | – | – | – | 1100 | 1000 | 870 | 013/0054 | 38 | 12 | ½" | – | 2800 | 2,6 | | BG G | 600 | 540 | 480 | 011/0021 | – | – | – | – | 38 | 12 | ½" | – | 1680 | 2,6 | | | | | | | | | | | | | | | | | BH P | 1000 | 700 | 600 | 011/0031 | – | – | – | – | 56 | 18 | ¾" | ¼" | 1680 | 6,4 | | BH M | 1500 | 1200 | 1000 | 011/0032 | – | – | – | – | 56 | 18 | ¾" | ¼" | 1680 | 6,4 | | BH G | 2000 | 1700 | 1400 | 011/0033 | – | – | – | – | 56 | 18 | ¾" | ¼" | 1680 | 6,4 | | | | | | | | | | | | | | | | | BHG P | 3000 | 2200 | 2000 | 011/0043 | – | – | – | – | 75 | 22 | 1 ½" | – | 1400 | 14,9 | | BHG PZ | 3700 | 3000 | 2700 | 011/0080 | – | – | – | – | 75 | 22 | 1 ½" | – | 1400 | 14,9 | | BHG M | 4500 | 3600 | 3200 | 011/0044 | – | – | – | – | 75 | 22 | 1 ½" | – | 1400 | 14,9 | | BHG G | 6000 | 4800 | – | 011/0045 | – | – | – | – | 75 | 22 | 1 ½" | – | 1400 | 14,9 | | |  | | hp internal gear pumps up to 40 bar (Direction D = direct - clockwise) | Pump Series B Size: | Viscosity: 6 mm2 sec-1 at 20° C | Gear Rotor Size Ø | Shaft Ø | Threaded Connection for (S/A) | Mano-meter Con-nection | Heating Capacity H1 in Watt at 220V, 50Hz at I/D | Initial Pump Breakaway Torque at I/D | n = 1400 min-1 Discharge l/h | n = 2800 min-1 Discharge l/h | at 9 bar | at 30 bar | at 40 bar | Article No. D | at 9 bar | at 30 bar | at 40 bar | Article No. D | | BP | 45 | 30 | 20 | 012/0002 | 90 | 60 | 50 | 014/0002 | 25 | 12 | 3/8" | – | 100 | 1,2 | | BM | 80 | 60 | 50 | 012/0003 | 160 | 130 | 120 | 014/0003 | 25 | 12 | 3/8" | – | 100 | 1,2 | | BG | 120 | 100 | 80 | 012/0004 | 240 | 200 | 190 | 014/0004 | 25 | 12 | 3/8" | – | 100 | 1,2 | | BF | 160 | 140 | 120 | 012/0005 | 320 | 270 | 260 | 014/0005 | 25 | 12 | 3/8" | – | 100 | 1,2 | | | | | | | | | | | | | | | | | BG PP | 150 | 100 | 80 | 012/0052 | 300 | 240 | 210 | 014/0052 | 38 | 12 | ½" | – | 100 | 1,6 | | BG PZ | 200 | 160 | 140 | 012/0053 | 400 | 310 | 280 | 014/0053 | 38 | 12 | ½" | – | 100 | 1,6 | | BG P | 300 | 240 | 200 | 012/0019 | 600 | 520 | 480 | 014/0019 | 38 | 12 | ½" | – | 100 | 1,6 | | BG MZ | – | – | – | – | 850 | 750 | 700 | 014/0068 | 38 | 12 | ½" | – | 100 | 1,6 | | BG M | 450 | 390 | 360 | 012/0020 | 900 | 800 | 730 | 014/0020 | 38 | 12 | ½" | – | 100 | 1,6 | | BG GZ | – | – | – | – | 1100 | 930 | 870 | 014/0054 | 38 | 12 | ½" | – | 100 | 1,6 | | BG G | 600 | 540 | 480 | 012/0021 | – | – | – | – | 38 | 12 | ½" | – | 100 | 1,6 | | | | | | | | | | | | | | | | | BH P | 1000 | 700 | 600 | 012/0031 | – | – | – | – | 56 | 18 | ¾" | ¼" | 160 | 3,2 | | BH M | 1500 | 1200 | 1000 | 012/0032 | – | – | – | – | 56 | 18 | ¾" | ¼" | 160 | 3,2 | | BH G | 2000 | 1700 | 1400 | 012/0033 | – | – | – | – | 56 | 18 | ¾" | ¼" | 160 | 3,2 | | | | | | | | | | | | | | | | | BHG P | 3000 | 2200 | 2000 | 012/0043 | – | – | – | – | 75 | 22 | 1 ½" | – | 280 | 4,6 | | BHG PZ | 3700 | 3000 | 2700 | 012/0080 | – | – | – | – | 75 | 22 | 1 ½" | – | 280 | 4,6 | | BHG M | 4500 | 3600 | 3200 | 012/0044 | – | – | – | – | 75 | 22 | 1 ½" | – | 280 | 4,6 | | BHG G | 6000 | 4800 | – | 012/0045 | – | – | – | – | 75 | 22 | 1 ½" | – | 280 | 4,6 | | To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site! The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used. |  |  |  |  |  | Gear Rotor Size | Discharge l/h | a1 | a2 | a3 | b1 | c1 | c2 | c3 | c4 | c5 | c6 | c7 | c8 | d1 | | 1400 min-1 | 2800 min-1 | | 25 | 45 - 160 | 90 - 320 | 35,5 | 20 | 33 | 51 | 41,5 | 14 | 16 | 40 | 20 | 55,5 | 76 | 131,5 | 12 | | 38 | 150 - 600 | 300 - 1100 | 43 | 26,5 | 38 | 70 | 55,5 | 14 | 16 | 40 | 20 | 69,5 | 76 | 145,5 | 12 | | 56 | 1000 - 2000 | – | 48,5 | 38 | 45 | 96 | 71,5 | 15 | 18 | 79 | 27 | 86,5 | 124 | 210,5 | 18 | | 75 | 3000 - 6000 | – | 64,5 | 83 | 70 | 115 | 129,5 | 18 | 25 | 65 | 37 | 147,5 | 127 | 274,5 | 22 | |  | Gear Rotor Size | Discharge l/h | sw | e | d2 | d3 | e1 | e2 | f2 | f3 | f4 | g1 | h1 | h2 | h3 | | 1400 min-1 | 2800 min-1 | | 25 | 45 - 160 | 90 - 320 | 27 | 31,2 | 54 | 80 | G 3/8" | 71 | 16,5 | 38 | 92 | 43 | 11 | 13 | 13 | | 38 | 150 - 600 | 300 - 1100 | 27 | 31,2 | 54 | 80 | G ½" | 82 | 19 | 44 | 92 | 43 | 11 | 13 | 13 | | 56 | 1000 - 2000 | – | 46 | 53,1 | 60 | 100 | G ¾" | 112 | 22,5 | 67 | 120 | 65 | 13 | 13 | 25 | | 75 | 3000 - 6000 | – | 55 | 63,5 | 80 | 120 | G 1 ½" | 170 | 35 | 100 | 150 | 90 | 14,5 | 15 | – | | | | | 直销德国欧洲机电工控设备配件 安诺科技(北京恒远安诺科技有限公司),致力于为客户提供德国及欧洲生产的各类工控机电设备、仪器仪表、零配件,保证100%原装*。公司总部设在欧洲航空中心法兰克福,距法兰克福机场仅35km, 通过拼单发货的物流方式,小订单也不用承担高运费,zui大程度地为客户节省采购成本,因此本公司所有产品均不设zui小订单金额或zui小订购数量。 通过从德国工厂直接采购,您可以避免国内代理、办事处和经销商的分级代理,层层盘剥的模式,享受到价格低货期短的采购服务。对于一些德国产品,我们通过集中批量采购以获取厂商*折扣,可以提供比国内市场价格更低的报价。对于不太容易找到的德国及欧洲小品牌的工业产品,我们可以帮助您寻找并代为采购,为本公司直接供货的欧洲中小企业已达1000多家。 以规范的管理,流程化的采购模式,健全的物流管理,*的售后服务,我们竭诚为您服务!欧洲所有进口产品都能采购。只要您提供品牌和型号,其余的事情交给我们!为了提高报价效率,请您务必提供品牌、型号、货号、数量或者铭牌照片。 只要您提供品牌和型号,其余的事情交给我们! 钱 : -8010 -8010 或发送电子邮件至:1095688308 |